pas s i ve
c r os s over
Connector wiring
Faston type connector, male single PG (standard), dual PG
(optional)
6
2.2 Connections
The cabinet is fitted with two NL4 M connectors. All four pins of
both connectors are wired in parallel. It uses the pin assignments
1+/1–. Pins 2+/2– are designated to actively driven subwoofers.
Using one connector as the input, the second connector allows for
direct connection to a second cabinet.
NL4 M
1+
d&b LoadMatch
With the d&b four channel amplifier platform, the LoadMatch
function enables the amplifier to electrically compensate for the
properties of the loudspeaker cable used without the need for an
additional sense wire. For applicable loudspeakers, LoadMatch is
therefore independent of the connector type used.
WR option (Weather Resistance)
A number of d&b loudspeakers are available in special options
suitable for different types of installed applications and
environmental conditions. The following options are available for
the Ti10L loudspeaker:
▪ Weather resistant (WR): This option is suitable for outdoor use.
The cabinets have an impact and weather protected black PCP
(Polyurea Cabinet Protection) finish.
WR cabinets are equipped with a recessed connector panel
including a Faston type connector (2 x 6.3 mm, female). A cover
plate which accepts single or dual PG cable glands (Type PG13.5
for cable diameters from 6 - 12 mm) is enclosed, as shown in the
graphic opposite.
To install the fixed connection cable, please proceed as follows:
Tools required: Screw driver (#T20).
Note: Observe the correct polarity of the cable
Brown (+) / Blue (—).
1. Insert the connection cable through the PG screwing and
connect the male connector to the female connector.
2. Push the cover plate towards the connector panel until it fits
into place.
3. Fix the cover plate to the connector panel using the four
countersunk screws.
2.3 Operation
NOTICE!
Only operate d&b loudspeakers with a correctly configured d&b
amplifier, otherwise there is a risk of damaging the loudspeaker
components.
Applicable d&b amplifiers:
30D/10D/D80/D20/D12/D6.
1–
2+
2–