1. INTRODUCTION
IF16T is a curtain pir sensor, can create a barrier of protection useful for doors and windows.
And it is possible set a delay system activation.
2. DELAY SYSTEM ACTIVATION FUNCTION (DIP4 - DIP5)
Turning ON the DIP introduces a time delay between the instant of the sensor detects the move-
ments and the instant at which trigger the alarm relay. After the first violation, the sensor will count
the set time, after this time and for more 10 sec. there will be some movement, turn in alarm, if after
the set time there will be no movements, the sensor will go into reset.
3. INSTALLING AND SETTING
The sensor is designed to be installed to protect the openings, for example between the window
and the shutter, or to doors and gates. Due to the high angle of coverage and the ability to rotate
the lens on the support of the pyroelectric, you can install it in different ways, from top to bottom or
on one side.
For the dip switch settings see the diagram below
DIP-SWITCH
DIP 1-6-7-8
not used
DIP 2
walk led OFF
DIP 3
2mt coverage
DIP 4
immediate alarm
DIP 5
immediate alarm
4. INSTALLATION AND CONNECTIONS
Choose a suitable location, mount the sensor using the turrets tear to get the tamper protection.
The cable can go from a tiny hole next to the terminals, or if the section is very large, you can switch
from the knock-out (see figure below)
Fixed base rear slide the cable through the holes selected, secure the board in its housing interlo-
cking and fix the cables into the appropriate terminals.Fix with screw the top.
In the figure at the end of manual, you can see different types of installation, in the center of the
window or on a side. The drawings are for guidance only, so you should always test the sensor.
5. WARM UP AND OPERATION
At start up the sensor needs a warm up time, this time is about 40''. There will be fewer violations
during this time is the faster entry into operational mode.
Operating without options: when the sensor is ready ,after the first violation, the waiting time for
second violation is a few seconds (5 sec. max).
Operation with delay times (dip 4 - 5): with the delay time set, you can access protected air wi-
thout giving alarm, so you can access the system without disarm. After this time, the sensor resets
without giving alarm. If after the set time for more 20seconds, the sensor detects movement still
give alarm.
www.amcelettronica.com
IF16T
OFF
walk led ON
3.5mt coverage
Delayed 30'' + 10'' (dip4 ON + dip5 ON = 1'30'')
Delayed 1' (you can add the time at 1'30"with dip)
IF16T
TELEPITŐ
INSTALLATION
ON
installation instructions