Flomec G Series Manual do proprietário do produto - Página 3

Procurar online ou descarregar pdf Manual do proprietário do produto para Instrumentos de medição Flomec G Series. Flomec G Series 20 páginas. Industrial and chemical models
Também para Flomec G Series: Manual do Proprietário (16 páginas), Manual do proprietário do produto (20 páginas)

Flomec G Series Manual do proprietário do produto
This manual will assist you in installing and maintaining your FLOMEC G-Series
Sanitary Turbine. For best results, take the time to fully acquaint yourself with all
information about all components of your G-Series Sanitary Turbine. If you need
assistance, contact the distributor from whom you purchased your turbine.
Product Description
FLOMEC G-Series Sanitary Turbine flowmeters are volumetric flow measurement
devices. The moving fluid is used to turn a rotor, which is suspended in the flow
stream. The rotating speed of the rotor is proportional to the fluid velocity or
flowrate. As the blades from a spinning rotor pass by a magnetic sensor, an AC
voltage pulse is generated and transmitted to the readout instrument. Each pulse
is equal to a given volume of liquid; therefore "x" number of pulses are equal to a
gallon, litre, pound, barrel, etc.
Turbine Sizing
FLOMEC G-Series Sanitary Turbines are identified by the internal diameter of the
inlet and outlet.
Model 100
Model 100L
Model 150
Model 150L
Model 200
Model 200L
Turbine flowmeters should be sized in accordance to the actual flowrate and not
the process pipe size. For example, a process having a flowrate of 10-20 GPM in
a 1-1/2 in. process line requires Model 100 OR 100L turbine flowmeter.
Another important factor to take into consideration when sizing a turbine flowmeter
is instantaneous flowrate. This is extremely important when sizing a turbine
flowmeter where the volume is measured per hour or per day. For example, an
application where the total output is 500 barrels per day, occurring in a 5-hour
period; the recommended turbine flowmeter should be sized according to the
instantaneous flowrate:
(500 – 5) x 24 or 2,400 barrels per day
Thus, requiring a 1-1/2 inch turbine flowmeter.

GENERAL INFORMATION

1 in.
(6.7-67 GPM)
1 in.
(6.7-67 GPM)
1-1/2 in.
(17.7-177 GPM)
1-1/2 in.
(17.7-177 GPM)
2 in.
(33-330 GPM)
2 in.
(33-330 GPM)
3