Dontek AQUASMART 5 SV Manual de instruções - Página 6

Procurar online ou descarregar pdf Manual de instruções para Controlador Dontek AQUASMART 5 SV. Dontek AQUASMART 5 SV 13 páginas.

ENTER BUTTON
Pressing the ENTER button will turn on the LCD backlight. Pressing the ENTER button while the backlight is lit will
enter the SETTINGS MENU. The following will be displayed:
1) EXIT, the menu system can be navigated using the ↑ or ↓ buttons. All selectable and changeable values will
flash on the LCD screen. Press the ENTER button to accept the currently displayed (flashing) item.
All menu items are shown below:
1) EXIT
2) HEATER TIMERS
3) SYSTEM
1) EXIT
Will save changes and return to automatic operation.
HEATER RUN TIMES – When the HEATER RUN TIMES is selected the following is displayed:
No. OF TIMES PER
DAY TO RUN: x
Select the number of times per day you wish the AUX Heating to operate. If OFF is selected
then the pump will only operate for Solar Heating purposes, otherwise the following is
displayed:
One time per day menu:
HEATER CYCLE 1 menu:
HEATER CYCLE
xx:xx TO xx:xx
Twice per day HEATER CYCLE 2 menu:
HEATER CYCLE 1
xx:xx TO xx:xx
2) HEATER
Adjust the start time and end time for the required heater cycle(s). The circulation pump will
TIMERS
run between these times for AUX heating purposes.
**Factory Default is ON, ONE TIME PER DAY FROM 06:00 to 22:00.
Note 1: Take care not to overlap heater cycle 2 times with the heater cycle 1 times as the
result will be one cycle per day.
Note 2: For 24hr heating, set the heating to run 1 time per day with the start & end times
the same (E.g. 12:00 – 12:00).
Note 3: If the unit is configured to run the heater parallel to the solar, the controller will
not run the heater in conjunction with the solar collectors. It will only run them
individually.
Note 4: When the roof temp probe exceeds the AUX LIMIT + 15
energy to heat the pool. The auxiliary heating is switched off to save energy. The auxiliary
heater remains switched off until the roof temperature drops below AUX LIMIT + 10
won't matter if the controller has been configured to run the heater parallel or in-line with
the solar for this to occur.
EXIT - Press ENTER on this menu to return to automatic operation.
SET CLOCK – Allows you to adjust calendar date and time of day.
3) SYSTEM
LCD BACKLIGHT – Adjust the number of seconds the backlight remains on after the time a
button was pressed. (Select NONE for always on.)
AQUASMART 5 SV v1.4
HEATER CYCLE 2
xx:xx TO xx:xx
o
C, there is enough solar
o
C. It
6