PROBLEM
Bag is not sealed in the
middle
Bag is not being
vacuumed
Bag looses its vacuum
after time
Element sparks or
breaks on the left side
Machine does not turn
on
TROUBLESHOOTING
CAUSE
Red Rubber might be
indented providing less
seal pressure.
Low air pressure
Low air pressure
Bag is closing around the
tip of the nozzle
Bag material might be
porous
Bag might have been
punctured by sharp
corner
Element is being held by
the post only and not
tightly between and by
the washers
Blown fuse
SOLUTION
Replace Red Rubber
and Teflon (Pressure Bar
Kit)
Make sure air pressure is
set to 100 to 110 psi,
free air flow of 6CFM is
needed
Make sure air pressure is
set to 100 to 110 psi,
free air flow of 6CFM is
needed
Keep product as close to
the tip of the nozzle as
possible
Use a bag made for
vacuum. Do not use
channel bags
Use thicker bag or lower
vacuum level (An
optional Vacuum
Regulator might be
needed)
Follow yellow-bold
instructions on step #4 of
"Installing new element"
section of the Basic
Service Instructions
Replace fuse – located
on the power receptacle,
pry open fuse drawer
with small flat
screwdriver. Fuse
Drawer has spare
included