DoorHan PCB-SH380 Manual de instruções de programação - Página 7

Procurar online ou descarregar pdf Manual de instruções de programação para Painel de controlo DoorHan PCB-SH380. DoorHan PCB-SH380 8 páginas.

DoorHan PCB-SH380 Manual de instruções de programação

2. OPERATOR PROGRAMMING

Programming of the operator is accomplished by DIP switch keys.
In order to choose the program logic of the operator install DIP switch keys to the appropriate position according to the
description pointed out below:
On
DIP3
DIP2
DIP1
WARNING! It is recommended to use pulse logic for door closing only if safety photocells are available.
DIP1 — Is in charge of automatic closing of the operator
Off
ON — Automatic closing is switched on (30 seconds)
OFF — Automatic closing is switched off
DIP2 — Is in charge of the program logic of the operator on closing
ON — Closing is accomplished by holding the button
OFF — Closing is accomplished by impulse pressing of the button
DIP3 — Is in charge of the program logic of the operator on opening
ON — Opening is accomplished by holding the button
OFF — Opening is accomplished by impulse pressing of the button
OPERATOR PROGRAMMING