09. CHECK TOP LATCH FOR HOLDBACK AND DEADLOCK
Adjustment Screw
1. Pushing on push bar will retract the latchbolt and
allow the door to open. Latchbolt will stay
retracted, if not adjust the screw on top of the
retractor with a screw driver.
09. CHECK TOP LATCH FOR HOLDBACK AND
DEADLOCK (SECURE TOP STRIKE)
DXAS106
E
3rd Strike Screw
DXAS108
E
Strike Screw
Once the latchbolt is adjusted properly and engages
with the strike when the door is closed and retracts
when the door is opened; install any additional
screw(s) required to firmly secure the strike used.
2. Once the door is closed, the strike will engage with the deadlock, which
will allow the latchbolt to extend and engage behind the strike. The
latchbolt cannot be retracted when the door is closed and the deadlock
depressed. If not, adjust the strike position to engage with the device
deadlock.
DXAS215
E
Strike Screws
Close
10. INSTALL BOTTOM LATCH AND ROD
FOR LESS BOTTOM ROD MODELS (LBR) OMIT THIS STEP
AND INSTALL AUXILIARY LATCH BOLT.
L
Connecting Bar
Screws
Sleeve
Rod
Latch Screws
F
Bottom Latch
1. Install bottom latch with two screws (or with through-bolts for fire
model).
2. Pass bottom rod through rod guide and attach connecting bar to top
of rod
3. Thread the bottom of the rod into the stud of the bottom latch until
the first holes in the end of the connecting bar align with the first
holes in the retractor and fasten with side screws
4. Ensure the bottom strike is properly aligned to engage with the
bottom latchbolt.
8 / 12
Open
Retractor
Side
H
Sex Bolts
First Holes
Side
Screws
Second
Holes