DORIC DS2079 Instruções de instalação - Página 2

Procurar online ou descarregar pdf Instruções de instalação para Por fechaduras DORIC DS2079. DORIC DS2079 2 páginas. Multi point

Extrusion Cut Outs
Assembling top and bottom locks to rods
ABOVE THE CENTRE LINE
1. Preasemble and connect
the top and bottom operating
rods to the Actuator bar.
BELOW THE CENTRE LINE
2
www.doric.com.au
2. Feed the top and bottom operating
rods fitted with the actuating bar through
the the top cut. Do not fully
insert slave locks into cutouts.
3. With the top slave unit in the locked
position, attach the top rod.
4. Find and pull the bottom out through the
bottom cutout.
Fitting Centre lock
5.Fully insert centre lock into cut out.
Secure centre lock with two 12mm
countresink self tapping screws supplied.
6. Fully insert the slave locks and secure
with 12mm countersink self tapping
screws.