EXPAND SERIAL COMMAD FUNCTIONAL SPECIFICATION for LV-5210/7215/7210
Unacceptable
8.11.8 CF_ON-STACOMMAND
COMMAND
"CF_ON-STA_%1" [CR]
"ON"------ Select Power On Start
%1
"OFF"---- Cancel Power On Start
Set/Cancel Power ON Start. (Only valid when it is in the usual Power ON
status.)
Details
The value set is stored in EEPROM. When ALL OFF the projector, the
value will return to the original setting.
Acceptable
Response
Unacceptable
8.11.9 CF_P-MANECOMMAND
COMMAND
"CF_P-MANE_%1" [CR]
"OFF"------------ Set Power management to OFF
%1
"READY"-------- Set Power management to Ready
"SHUTDOWN"-- Set Power management to Shut Down
Set/Cancel Power management.(Only valid when it is in the usual Power ON
status.)
Details
The value set is stored in EEPROM. When ALL OFF the projector, the
value will return to the original setting.
Acceptable
Response
Unacceptable
8.11.10 CF_P-MANETIMECOMMAND
COMMAND
"CF_P-MANETIME_%1" [CR]
"01"-"30"-- Directly set the time by the minute
%1
"UP"------------ Set the time 1 minute longer
"DN"------------ Set the time 1 minute shorter
Set Power management time. (Only valid when it is in the usual Power ON
status.)
Details
The value set is stored in EEPROM. When ALL OFF the projector, the
value will return to the original setting.
Acceptable
Response
Unacceptable
8.11.11 CF_FANSPEEDCOMMAND
COMMAND
"CF_FANSPEED_%1" [CR]
"MAX"------Select maximum speed
%1
"NOR"------Select NORMAL speed
Change Fan Control speed.
Details
status.)
The value set is stored in EEPROM
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
Only valid when it is in the usual Power ON
When ALL OFF the projector the
Page