Battery Fighter BCA1102S6WR Manual de instruções - Página 4

Procurar online ou descarregar pdf Manual de instruções para Carregador de bateria Battery Fighter BCA1102S6WR. Battery Fighter BCA1102S6WR 8 páginas. Intelligent battery charger for both 6v & 12v lead acid automotive batteries

SELECTION FOR BATTERY TYPE
A.C. power is connected with the wall socket properly
Press MODE button for battery charge mode selection before you connect the charger to the battery terminals.
LED Signal
12V 1A
6V 1A

LIGHT INDICATION:

LED SIGNAL
POWER
MODE
6V 1A
12V 1A
REVERSE POLARITY
RECOVERY
FULLY CHARGE /
MAINTENANCE
BAD BATTERY
CHARGING
BCA1382S6WR - 140728
Explanation
Lead Acid charging
Lead Acid charging
A.C. power is connected with the wall socket properly and self-test will be commenced, the
LEDs will be flashing in following sequence - Bad Battery LED -> 12V 1A LED -> Recovery
LED -> 6V 1A LED. After completed the self-test, it will enter into standby mode. Standby :
POWER LED is flashing ; Charging : POWER LED is glowing
Press the MODE button for the selection of charging program.
PB charging status : the charger is switched to 6V lead acid (Pb) battery charging mode with
maximum current 1A
PB charging status : the charger is switched to 12V lead acid (Pb) battery charging mode with
maximum current 1A
Battery is connected in reverse polarity, please check the battery connection(s) and correct
reverse polarity condition. ( Make sure Red to "+" and Black to "-")
Battery Recovery processes will commence if the charger detects any charge acceptance
problems. Recovery processes include: Battery Rescue Phase, Soft Start Phase, Pulse Mode
Phase and Recondition Phase. Once the Recovery processes are completed, normal charge
will commence immediately. Recovery function in effect for Lead Acid charging mode 12V 1A
only.
The charging process is completed and the battery is in maintenance mode, it can be
returned to service if necessary or left safely connected to the charger indefinitely.
Maintenance function in effect for Lead Acid charging mode – both 12V 1A & 6V 1A. The LED
will be flashing while approaching fully charged and glowing in fully charge or maintenance
stage
The battery is worn out or is possibly defective. Suggest replacing battery ASAP
Normal charge processes are commenced. The Charger is delivering constant current &
voltage to the battery. To charge large capacity batteries the charger may remain in this mode
for several hours or even days. The Charging LED is in RED when the battery capacity is less
Description
12V lead acid battery charge mode at 1A max.
6V lead acid battery charge mode at 1A max.
EXPLANATION