Power input (line) wiring
The DMX24DIM should be connected to a standard 15A 120VAC grounded outlet. The outlet must
be protected by an appropriate over-current protection device.
Note that if all outputs are loaded to 100W and all outputs are set to full, the 15A branch breaker
feeding the DMX24DIM or DMX24DIM-2U will trip. If the application requires all dimmers to be fully
loaded, the DMX24DIM or DMX24DIM-2U must be fed by a 20A branch breaker and an appropriate
receptacle. The standard 15A mains plug on the DMX24DIM or DMX24DIM-2U must be replaced
with an appropriate 20A connector.
Power output (load) wiring
Each output can supply a 100W (maximum) 120VAC load. Each output on the DMX24DIM uses a
polarized ungrounded parallel blade connector (NEMA1-15R). The DMX24DIM-2U uses grounded
parallel blade connectors (NEMA5-15). Cables should only be connected and disconnected while the
dimmer outputs are off or the input power to the unit is removed.
Control cable wiring
Standard 5 pin XLR cables should be used to connect DMX512 signals to the connectors on the front
panel of the DMX24DIM or DMX24DIM-2U. A male input is provided and a passive female "thru"
output is provided. There is no internal termination. The last device in the DMX512 daisy chain
should be fitted with a DMX512 terminator.
Only pins 1, 2, and 3 are used by the DMX24DIM or DMX24DIM-2U, however all 5 pins are passed
through to the "thru" connector.