Baumer GXP5W Manual - Página 26

Procurar online ou descarregar pdf Manual para Conversor de multimédia Baumer GXP5W. Baumer GXP5W 41 páginas. Absolute encoder with canopen lift protocol
Também para Baumer GXP5W: Instruções de montagem (2 páginas)

Baumer GXP5W Manual
Object 2100
Baud Rate
Subindex
Data Type
Access
Default
EEPROM
Description
Values
Object 2101
Node-ID
Subindex
Data Type
Access
Default
EEPROM
Description
Values
Object 2110
Manufacturer_Options
Subindex
Data Type
Access
Default
EEPROM
Description
Values
Manual_GXP5_417_Lift_EN.doc
04.05.11
0
Unsigned 8
ReadWrite
2 = 50kBaud
Yes
Read or set new sensor baud rate.
After setting, parameters must be saved in EEPROM with Object
1010h and then sensor must be reinitialized
0
10 kBaud
1
20 kBaud
2
50 kBaud
3
100 kBaud
4
125 kBaud
5
250 kBaud
6
500 kBaud
7
800 kBaud
8
1000 kBaud
0
Unsigned 8
ReadWrite
1
Yes
Read or set new sensor Node-ID.
After setting, parameters must be saved in EEPROM with Object
1010h and then sensor must be reinitialized
1 - 127
0
Unsigned 32
ReadWrite
8h
Yes
Settings for ensuring compatibility to older sensors
Bit 3 =1 : Reset after Bus Off
26/41
Baumer IVO GmbH & Co. KG
Villingen-Schwenningen, Germany