7.3 Grounding
Earth/Machine Ground
The LLE is earth grounded through the process connection to the
tank with the assumption that the tank is grounded. If the tank is not
grounded then a ground will need to be connected to the housing of
the LLE. Without correct grounding the overvoltage protection will be
compromised.
Shield Ground
Immunity performance of the sensor from external sources of surge,
burst, RF, radiated emissions and other noise is dependent on a proper
ground for the shield of the communications cable. The communica-
tions cable shield should be of a braided type and connected to the
internals.
.
7.4 Wiring Connections
D34 Analog
Signal + power supply
M12 male connector
Pin
(A-coded)
1
2
2
3
5
1
3
4
4
View on sensor
5
Fig. 3: D34 Analog
D84 SSI
Signal + power supply
M12 male connector
Pin
(A-coded)
1
2
3
6
1
4
7
4
3
2
5
5
6
View on sensor
7
8
Fig. 4: D84 SSI
D44 IO-Link
Signal + power supply
M12 A-coded
Pin
Function
1
+24 VDC (±25 %)
3
2
DI / DQ
4
2
3
DC Ground (0 V)
1
4
C / Q
Fig. 6: D44 IO-Link
Function
+24 VDC (−15 / +20 %)
Output 1
DC Ground (0 V)
Output 2
DC Ground
Function
Clock (+)
Clock (−)
Data (+)
Data (−)
Not connected
Not connected
+24 VDC (−15 / +20 %)
DC Ground (0 V)
D34 CAN
Signal + power supply
M12 male connector
(A-coded)
2
3
5
1
4
View on sensor
Fig. 5: D34 CAN
T84 Analog + RTD
Signal + power supply
M12 male connector
(A-coded)
6
1
7
4
3
2
5
View on sensor
Fig. 7: T84 Analog + RTD
I
16
I
Pin
Function
1
Shield
2
+24 VDC (−15 / +20 %)
3
DC Ground (0 V)
4
CAN_H
5
CAN_L
Pin
Function
1
Clock (+)
2
Clock (−)
3
Data (+)
4
Data (−)
5
Not connected
6
Not connected
7
+24 VDC (−15 / +20 %)
8
DC Ground (0 V)