Specifications

Electrical
§ Freestanding and countertop models (110FB425A/W, 110CT425A/W) require a dedicated circuit.
Basic electrical: 115 V/60 Hz/1 phase
§ Dispensers and ice machines are supplied with 7-foot power cord with NEMA 5-15 hospital-grade plug. Connect
to a dedicated 15A circuit.
Model
110FB425A/W
110CT425A/W
Ambient
Air temp*
Water temp
Water pressure (psi/bar)
Ambient air temperature is measured at the air-cooled condenser coil inlet.
*
Ambient water temperature is measured in the ice machine reservoir.
Plumbing
Dispenser drain
Ice machine drain
Dispenser water inlet
Ice machine water inlet
Cond. inlet – w/c only
Cond. drain – w/c only
Note: Water shut-off recommended within 10 ft (3 m) of dispenser. Drain to be hard-piped and insulated. Maintain at
least 1/4" per foot (20 mm per 1 m) run of slope.
Ventilation clearances
§ 110CT425A/W: 6" (15.2 cm) required at top.
Note: 6" (15.2 cm) at each side advised for service.
§ 110FB425A/W: 4" (10.2 cm) required at rear .
Note: 12" (30.5 cm) at top advised for service.
Approximate shipping weight
§ 290 lb (132 kg), base stand: 140 lb (64 kg)
Total system
11.0A
Electrical connection
cord & plug provided
cord & plug provided
100 F/38 C Max.
50 F/10 C Min. (Best performance below 80 F/27 C)
90 F/32 C Max.
45 F/7.2 C Min. (Best performance below 70 F/21 C)
70/5 Max.
10/0.7 Min.
110CT with integral ice
machine
3/4" MPT
3/4 MPT
3/8" FPT
3/8" FPT
3/8" FPT
3/8" FPT
Max. circuit
20A
Circuits required
115/60/1, 15A max. fuse size
115/60/1, 15A max. fuse size
110FB with ice machine
in base
3/4" MPT
3/4" MPT
3/8" FPT
3/8" FPT
3/8" FPT
110CT425A/W, 110FB425A/W
3