3.2.5
Pressing the SETTINGS DISPLAY (blue button) allows the settings of the
meter to be reviewed and later changed if required (these contain some
settings that only the landlord can view):
3.3

Typical Menu for Single Rate Meters

RATE 1 010.00ppu
The set cost per kWh on Rate 1 (pence per unit).
DEBT/WK £000.00
The Debt Collection rate per week.
T.DEBT £0000.00
The total outstanding debt.
STCH/WK £000.00
The standing charge rate applied per week.
TIME 22:27
Time now.
E.CRED £000.00
The Emergency Credit Value allowed.
E.AVAIL £000.00
The Emergency Credit allowed only if credit below this value.
PROGRAMMING
END
3.4

Typical Menu for Dual Rate Meters

TIME 22:27
Time now.
DATE 24/01/2010
Today's date.
T.CREDIT £00001
The total amount of credit inserted into the meter.
T.CARDS 00001
The total number of cards used to insert credit into the meter.
STCH/WK £000.00
The standing charge rate applied per week.
KWH 08713.42 R1
The total number of kWh consumed at Rate 1.
KWH 01150.23 R2
The total number of kWh consumed at Rate 2.*
RATE 1 010.00ppu
The set cost per kWh on Rate 1 (pence per unit).
RATE 2 010.00ppu
The set cost per kWh on Rate 2 (pence per unit).*
KWH 09863.65 TOT
The total energy passed through the meter.
E.CRED £000.00
The Emergency Credit Value allowed.
DEBT/WK £000.00
The Debt Collection rate per week.
T.DEBT £0000.00
The total outstanding debt.
PROGRAM NO 24
Our standard default program for the change of rates.
07:30 R1 AW AY M
The start time of the Morning R1 rate.
00:30 R2 AW AY A
The start time of the Afternoon R2 rate.
00:00 R? ? ? M
Next tariff change point (if desired). Up to 15 possible.
AREA CODE 103
The original card type for the meter (modified by us for use
with SHOCKWAVES cards).
PROGRAMMING
END
PAGE 7 of 16
Cardmeter User Manual ver 008 2016-02-24.doc
3.4.1
To change a setting, press the EMERGENCY CREDIT (grey button) and a
cursor will appear.
3.4.2
This can be tabbed across under the text by using the SETTINGS
DISPLAY (blue button). To change a value, do not release the
EMERGENCY CREDIT button, but press the SETTINGS DISPLAY
button simultaneously to change the value. If you miss the value you want,
continue and the required value will come around again.
3.4.3
Press the SETTINGS DISPLAY button on its own to store the new setting.