Amsino PUGGLE Configuração rápida - Página 2
Procurar online ou descarregar pdf Configuração rápida para Bomba de água Amsino PUGGLE. Amsino PUGGLE 2 páginas. Enteral feeding pump
Também para Amsino PUGGLE: Manual de referência rápida (12 páginas)
Action
2 steps to launch priming:
• Press
– Prime message appears
• Press multifunction button
[ ] – Launch prime
After the 1 min. 25 sec. priming
is completed or after pressing
multifunction button [ ]
Press multifunction button [ ]
Action
Press
or
then multifunction
button [ ]
Press
or
then multifunction
button [ ]
Press multifunction button [ ]
Press multifunction button [ ]
*Use entire bag: If the user selects the multifunction button [ ], the pump will be programmed to operate without setting a specific volume.
The pump will operate until the feeding bag is empty.
Locking Keypad
During the feeding, it is possible to lock the keypad. This feature allows deactivation
of the keypad buttons. When the keypad is locked, the pump cannot be paused or
switched off. To lock the keypad press and buttons together for 3 seconds. Do the
same action to unlock it. The key icon [ ] appears in notification header when the
keypad is locked.
Special case: When the alarm is triggered, the keypad automatically unlocks.
Tube Priming
Effect
• Automatically primes pump tubing
• Duration: Approx. 1 min. 25 sec.
• Automatic priming may be stopped
before completion by pressing
multifunction button [ ]
• Priming is completed
• Verify the tubing is fully primed
• Program the feeding
Programing Nutrition – Continual Feeding
Effect
• Set the flow rate from 1 to 400 mL/h
Choose your volume option:
• Press
to use entire bag*
• Press
to set the volume to be
delivered (this value must be from
1 to 9,999 mL)
• Overview of the feeding parameters
(with or without a programmed
volume)
• Start the feeding (with or without a
programmed volume)
Screen Displays
Screen Displays
Amsino Medical Group Co. Ltd.
708 Corporate Center Drive, Pomona, CA 91768 USA
+1 800.632.6746 • fax: +1 909.626.3888 • [email protected]
Product(s) described may not be licensed or available for sale in all countries. Please
see the Instructions for Use/Operator's Manual for a complete listing of the indications,
contraindications, warnings and precautions. The symbol
registered in the U.S. Patent and Trademark Office and certain other countries. Puggle
is a registered trademark of Amsino Medical Group Co. Ltd. © Copyright 2023, Amsino
Medical Group Co. Ltd. All rights reserved.
®
indicates the trademark is
EN-US-2023-08-04