Testing the system
The EG320/EG340 Programmer can be used to test
the EG320/EG340 system. To test the system:
• Point the programmer at the IR transmitter/receiver
on the EG320/EG340 EMS.
• Press and hold the Test button on the programmer
until it beeps once.
• The LED fixture should turn on briefly to indicate
that the system is operating properly.
The test command may not be received by the
EG320/EG340 EMS on bright, sunny days. Try
getting closer to the EMS, or try testing later in the
day when the sunlight won't interfere as much with
communications. See the Troubleshooting section if
the fixture still will not turn on.
8
EMS Indicator Lights
The EG320/EG340 EMS has three indicator lights
which are visible from the ground at night. On bright
days, the lights may be difficult to see from the
ground, and a pair of binoculars can be used to see
the lights (do not look at the sun directly when operat-
ing binoculars).
The following table summarizes the behaviour of the
three EMS indicator lights:
Light symbol
Status
On (green)
Flashing (green)
Off
On (red)
Flashing (red)
Off
On (red)
DIM
Off
All 3 lights
Pulsing (all lights) Programming
© 2015, Carmanah Technologies Corporation. EG320-340_UserManual_76116RevA
EG320/EG340 USER MANUAL
tEStiNG thE SyStEM
Function
Not charging
(night detected)
Charging (day
detected)
No battery
connected
Load low/high
voltage discon-
nect (Load LVD/
HVD)
Load over-current
Load OK
Dimming due to
battery low/high
voltage discon-
nect (Battery
LVD/HVD)
Time-controlled
dimming