Aleph XC-1XTUK Manual

Procurar online ou descarregar pdf Manual para Sensores de segurança Aleph XC-1XTUK. Aleph XC-1XTUK 3 páginas. Xc-1xt series. outdoor dual technology intrusion detector 40ft l x 56 w (12m x 17m)

Description: XC-1XT provides unsurpassed wide area unsecured outdoor instruion detection.
Combining Microwave & PIR detection technologies the XC-1XT ensures excellent coverage without
nuisance alarms. Dual outputs allow the use of a single detector for annunciation and security,
or allow multiple functioning via different control device assignments.
Installation:
For best results install the XC-1XT at a mounting height between 6.6 ft.(2.0m) and 8.2 ft. (2.5m). Mount the unit so it is
looking into an area free of obstructions, do not mount the unit so it is looking directly at heating or cooling sources. Avoid
viewing operating machinery or objects which have the potential for movement. Do not aim unit so it is looking at public
road / pathways.
Wire the XC-1XT to the control panel device using 18 to 24 AWG standard non-shielded wire, do not run wiring parallel to
AC wiring. Wiring should be in accordance with NEC, NFPA 70 for North America.
Prior to re-attaching front cover to unit; Set PIR sensitivity, PulseCount, LED Enable, Detection mode, and 50/60Hz
Flourescent Light immunity setting (Selectable Switch 1,2,3,4,5, and 6) as desired.
If the detector is viewing a narrow area, a PC setting of 4 should be avoided, as the small area may not allow enough
movement to detect intruders. A PC of "4" is best suited for a wide open detection area. For High Security applications set
PIR Sensitivity to "High Sensitivity" =(SW1 & 2 = 120% or 100%), this allows for a quicker detection at the edge of the
detection area.
XC-1XT.
potentiometer to adjust Microwave sensitivity (Preset @ 50%). A properly adjusted MW will detect crossing movement just
inside the protected area but not outside of the PIR coverage area.
SW-5 allow for the selection of Dual-Technology (MW & PIR) or PIR only detection modes. A PIR only detection mode is
useful when there is operating machinery or exposed fans always active within the protected area.
If the installation site is subject to severe vibrations (via close proximity to railroad tracks and /or large truck movement),
ensure that the mounting point is on a riged surface. In some situations it may be necessary to place a piece of plywood
between the mounting surface and the XC-1XT detector to buffer wall movement.
Walk-Test:
Once installation and initial setup is complete, perform a full walk test to insure that the detection parameters are met, if
required make control adjustments to fine tune detection characteristics. In order to insure detection quality, the XC-1XT
should be tested routinely, with no more than a one year period between tests.
Function Select Switch
SW-1 & 2 :PIR Sensitivity
120%
OFF
ON
SW-1
SW-2
SW-3
SW-4 LED Enable
4 off - LED's Enabled
SW-4
4 on - LED's Disabled
SW-5
SW-5 Detection Mode
5 off - Dual (MW & PIR)
SW-6
5 on - PIR Only
SW-6 50/60 Hz
6 off - 60Hz
6 on - 50Hz
Switch ON
Switch OFF
XC-1XT SERIES
Outdoor Dual Technology Intrusion Detector
40FT L X 56 W (12m x 17m)
Animal Immunity characteristics are not available when a "High Sensitivity" setting is configured on the
Animal Immunity function is enabled by placing PIR Sensitivity at 60%. Use Microwave Sensitivity adjustment
100%
80%
60%
SW-3 Pulse Count
3 off - PC2
3 on - PC4
Tamper Switch
Control Layout and Configuration:
uW Module Do not Touch
PIR Detector Do not Touch
1
2
3
4
5
6
Terminal Configuration
TAMPER
ALARM 1
ALARM 2
T
T
NC NO C
NC NO
LED Indicators
Green = PIR
Red = Alarm
Amber = MW
Microwave Sensitivity
Adjustment
MIN.
MAX.
The Sensitivity Adjustment
allows for MW coverage to be
fine set to the protected area.
Preset = 50%
Max. = increases sensitivity
Min. = decreases sensitivity
SPARE
POWER
+
-
C