Comnet CLFE IPS Series Manual de instalação e operação - Página 6
Procurar online ou descarregar pdf Manual de instalação e operação para Interruptor Comnet CLFE IPS Series. Comnet CLFE IPS Series 19 páginas. High-power poe mid-span injector
INSTALLATION AND OPERATION MANUAL
System Configuration Window
The "System Configuration" window provides access to setting global configurations and status view of major
parameters.
User Inputs
Power Management Mode (PM)
» None: Power Management will not be performed by the firmware. User needs to power up the ports manually.
» Static /w Priority: Power is budgeted statically based on selected violation type.
› If violation type is "Class Based", then maximum permissible power for that class is budgeted.
› If violation type is "User Defined", then the configured user-defined limit is budgeted.
› If violation type is "None", then budgeted power is based on port mode.
› For Normal Mode the power budgeted is 16.2W
› For High Power Mode the power budgeted is based on ILIM/ICUT selected value.
· For ILIM/ICUT – 504/465 mA, the power budgeted is 22.5W
· For ILIM/ICUT – 563/545 mA, the power budgeted is 26.5W
· For ILIM/ICUT – 850/625 mA, the power budgeted is 31.6W
· For ILIM/ICUT – 850/725 mA, the power budgeted is 37.0W
» Static /wo Priority: Same as above except that port priority of the port is ignored.
» Static /wo Priority: Power is budgeted statically based on selected violation type.
› If violation type is "Class Based", then maximum permissible power for that class is budgeted.
› If violation type is "User Defined", then the configured user-defined limit is budgeted.
› If violation type is "None", then budgeted power is based on port mode.
› For Normal Mode the power budgeted is 16.2W
Tech SupporT: 1.888.678.9427
Figure 7: System Configuration Window
Power Management can be used in the following modes:
CLFE(X)IPS
INS_CLFE(X)IPS_REV–
12/15/11
PAGE 6