Compac TJ-T1300 Manual de instruções - Página 3

Procurar online ou descarregar pdf Manual de instruções para Valetes Compac TJ-T1300. Compac TJ-T1300 11 páginas.

Safety:
The use of this jack is limited to the removal and installation of transmissions and differentials.
When loaded, the transmission jack may be used on a short flat way and only with the jack in the
lowest position, with the rod completely inside (fig.5). Check that during transport the load do not
swing and suddenly fall.
Do not overload! Overloading may cause damages to persons or things.
It may be used with appropriate adapters manufactured especially for the jack to handle other
components, such as rear units and transfers cases, within the limitations specified.
Be sure that the vehicle is appropriately before repairs.
Warning:
Avoid decentral placement of the gravity of the load.
Decentral placement of the load might cause overturning of the damage to the jack.
This jack is designed for use on hard level surfaces capable of the load. Use on other than surfaces
can result in jack instability and possible loss load (fig.5).
The safety valve is calibrated and sealed by manufacturer; it is absolutely forbidden to tamper with
this valve or change its calibration.
Failure to heed this warning may result in loss of the load, damage to the jack and/or failure
resulting in personal injury or property damage.
Maintenance:
The hydraulic system (pump/cylinder) is a sealed system, that requires only of the moving parts. In
the hydraulic unit leaks oil or has to be dismantled for gasket replacement, you need to make the
pump working and slowly add through the filling hole. When the transmission jack is in the lowest
position. The oil level should not exceed the filling cap level. For dismantling apply to authorised
people.
Required quantity of oil: 0.95 lt.
The hydraulic system contain enough oil when the jack reaches the reaches highest position.
Warning:
A surplus of oil might cause troubles.
Use any hydraulic oil of gradation ISO32 (ref. Shell Tellus T37 or equivalent). NEVER USE BRAKE
FLUID.
Oil the pedal mechanical parts every 2 months with an high quality oil and grease the head
pumping element. In case of leaking from the hydraulic system replace the seals.
Inspections:
Before using each jack should be checked to leaks, damages, missing, loose and worn parts.
Each jack shall be inspected immediately if it is believed to have been subject to an abnormal load
or shock. It is recommended that this inspection be made supplier's skilled personnel.
It is recommended that an annual inspection of the jack made by a suppliers authorised specialist
and that defective and dangerous parts must be replaced with original spare parts supplied by the
manufacturer (see spare parts list).
Damaged jacks:
Every damaged very used or abnormally operating jack shall be removed from service.
Jacks destruction:
When the jack must be destructed materials must be recycled according to the country law in force.
3