Atlantic Ultraviolet S20 Manual do Proprietário - Página 10
Procurar online ou descarregar pdf Manual do Proprietário para Sistemas de filtragem de água Atlantic Ultraviolet S20. Atlantic Ultraviolet S20 20 páginas. High capacity systems
Q
S
UARTZ
LEEVE
Step 4 - Remove Gland Nuts
1.
Disconnect power to water purifier.
2.
Shut off water supply to water purifier via inlet and outlet shut off valves. Drain chamber by removing
drain plug. Once the chamber is completely drained, remove any old sealing tape from the threads of the drain
plug, rewrap with 1/2" wide Teflon
3. Follow the steps in " Lamp Installation or Replacement " to remove lamp.
!
CAUTION:
4.
Unscrew static gland nuts from each end of the chamber. Avoid striking quartz sleeve with static gland nut.
®
5.
Remove Teflon
washer and o-ring from both ends of quartz sleeve. Teflon
the static gland nut. If so, remove Teflon
6.
Carefully remove quartz sleeve from chamber. NOTE: It is advisable to support the quartz sleeve on the opposite
end with your finger so that it does not drop to the bottom of the chamber as it slides into the chamber.
7.
Once the quartz sleeve is removed, clean with alcohol or a mild, non-abrasive detergent. Stubborn stains usually
can be removed with a dilute hydrochloric acid. NOTE: Follow all manufacturer's instructions and precautions
when handling chemicals.
8. Reassemble in reverse order. Make sure the quartz sleeve protrudes an equal distance past each threaded nipple. Be
sure o-rings are placed on quartz sleeve before Teflon
9. Tighten static gland nuts firmly by hand only, DO NOT USE HAND TOOLS. Tightening with hand tools is likely
to cause quartz sleeve to break.
10. Slowly restore water supply to water purifier and check for leaks.
11. If no leaks occur, reinstall lamp, following the steps in " Lamp Installation or Replacement " section.
!
WARNING:
water purifier until lamp and both EASY-OFF™ end caps have been properly reinstalled.
10
R
, C
EMOVAL
LEANING OR
Figure 5 - Quartz Sleeve Cleaning or Replacement
Step 5 - Remove Washer & O-Ring
®
thread sealing tape, reinstall and tighten the drain plug.
Lamp and quartz sleeve are easily damaged. Exercise care when removing or replacing lamp.
®
washer from static gland nut before proceeding.
Germicidal ultraviolet rays are harmful to eyes and skin. Do not restore power to
R
EPLACEMENT
Step 6 - Remove Quartz Sleeve
®
washer will sometimes remain within
®
washer.