EPLACEMENT OF
1. Follow the steps in "Quartz Sleeve Removal" to remove lamp and quartz sleeve.
2. To prevent damage to the electrical components, it is necessary to separate the ballast housing from the purifier chamber.
SANITRON
® Model S2400 C the ballast housing is mounted to the purifier chamber using four (4) 1/4"-20 x 3/8"
On
long hex head bolts. Using a 7/16" wrench or an adjustable wrench, carefully remove the four (4) bolts with the lock and
flat washers, from along the top of the ballast housing, and set aside. Separate the housing from the chamber.
Keep ballast housing and mounting hardware in a clean, dry area.
3. Carefully remove as much of the broken quartz sleeve as possible, from each end of the chamber.
4. Remove chamber head clamp, by using a 7/16" wrench to loosen and remove the 1/4" nut from the head clamp.
5. Withdraw chamber head and wiper assembly, from the chamber.
6. Any broken pieces of the quartz sleeve can now be removed through the open end of the purifier chamber. Flush water
through chamber being careful to remove all quartz fragments from the interior of the chamber.
7. Carefully discard all pieces of the broken quartz sleeve.
8. Inspect the large O-ring used to seal the chamber and the chamber head. Make sure the O-ring is seated properly between
the chamber head ring and the flare of the chamber head.
9. Insert replacement quartz sleeve through each Teflon ® wiper segment, starting from the furthest segment working towards
the chamber head. Twisting the quartz sleeve will help work the quartz sleeve through the Teflon
end of the quartz sleeve with the threaded gland nipple of the chamber head, and pass the quartz sleeve through the chamber head.
10. To re-install, carefully slide the chamber head and wiper rod assembly, into the chamber, with drain port pointing down,
using your finger, support the far end of the quartz sleeve when passing it through the gland fitting of the chamber. Push
chamber head flange into the chamber until both flared ends, of the chamber and the head, mate against the O-ring.
11. Replace the head clamp around the flared ends of the head and chamber. Install the 1/4" nut and tighten, using a 7/16"
wrench, until approximately 3/4" to 7/8" of the bolt protrudes past the nut.
12. Center the quartz sleeve in the chamber, making sure the quartz sleeve protrudes an equal distance past each threaded
gland fitting, of the chamber.
13. Re-install o-rings, Teflon
washer. Tighten static gland nuts firmly by hand only, DO NOT USE HAND TOOLS. Tightening with hand tools is
likely to cause quartz sleeve to break.
14. Re-assemble ballast housing to purifier chamber, using hardware removed in Step 2.
NOTE: When re-assembling ballast housing to purifier chamber, electrical power cord should exit ballast housing from
the end mounted opposite the drain plug.
15. When all connections are complete, allow water to enter the water purifier at a low flow rate until the purifier is
pressurized. With the purifier pressurized, it should be checked for leaks.
16. See " Lamp Installation or Replacement " section to properly re-install the lamp into the water purifier.