Ventilation
The appliance may only be installed in a permanently ventilated room as specified in
the regulations. The air flow in the room where the appliance is installed should be
sufficient for proper gas combustion and ventilation of the area. The air intakes,
protected by grilles, must be of the appropriate size (see relevant regulations) and
placed in such a way that they cannot be even partially obstructed. The kitchen
should be kept adequately ventilated to disperse the heat and moisture produced by
the cooking processes: in particular, a window should be opened or a fan.
Discharge of combustion gas
The flue gases must be removed by means of hoods
connected to a natural draft chimney or fan extraction
system. An effective extraction system requires careful
design by an authorized specialist, and must meet
distances and regulatory positions. After installation, the
engineer must issue a certificate of conformity.
Gas Connection
Connection with copper tube:
 The connection to the gas supply network must
be made in such a way that no voltages are
applied to the appliance. The connection can be
made using the adapter of unit D with two conical
elements, always adjusted the board C supplied.
Connection with steel tube:
 Only use stainless steel hoses that comply with the relevant regulations, and
always seal C properly fit between fitting A and hose E.
 When connecting with a hose, make sure that the length of the pipe is not
more than 2 meters; also make sure that the hose does not touch moving
parts or that it is crushed.
ADAPTING TO OTHER GAS TYPES
Before proceeding with the adaptation, disconnect the device from the electric
current.