Atlas DAGNY Manual de instruções - Página 7
Procurar online ou descarregar pdf Manual de instruções para Ventilador Atlas DAGNY. Atlas DAGNY 10 páginas. Ceiling mounted rotational fan
MAKING THE ELECTRICAL
CONNECTIONS
Warning:
The power should have already
been disconnected. Follow the steps below to
connect the fan to your household wiring. Use
the wire nuts supplied with your fan. Secure
the wire nuts with electrical tape. Make sure
there are no loose strands or connections.
NOTE: The Hand Held Remote Control units
included with your ceiling fan are equipped
with 16 code combinations to prevent possible
interference from or to other remote units. The
frequency switches on your Receiver and
Transmitter units have been preset at the
factory. Please re-check to make sure the
switches on both units are set to the same
positions. The frequency settings should be
changed only in case of interference or if a
second or more remote controlled ceiling fans
are installed in the same room. Any code
combination will operate the ceiling fan and
light as long as the Receiver and Transmitter
units are set to the same codes (Fig. 10)
1. Insert Receiver into Hanger Bracket with
the flat side of the Receiver facing the ceiling.
(Fig. 11)
2. Motor to Receiver Electrical Connections:
Connect the WH ITE wire from the fan to the
WHITE wire marked "TO MOTOR N" from the
Receiver. Connect the BLACK wire from the
fan to the BLACK wire marked "TO MOTOR
L" from the Receiver. Proceed to secure all
wire connections with the plastic wire nuts
provided. Dagny has no light, so the blue
receiver "light" wire must be capped off to
avoid electrical shock. (Fig. 12)
Note: Fan must be installed from a maximum
distance of 40 feet from the transmitting unit
for proper signal transmission between the
transmitting unit and the fan's receiving unit.
3. Receiver to House Supply Wires Electrical
Connections:
Connect
(Neutral) from the outlet box to the WHITE
wire marked "AC in N" from the receiver.
Connect the BLACK wire (Hot) from the outlet
box to the BLACK wire marked "AC in L" from
the receiver. Secure all wire connections with
the plastic wire nuts provided. (Fig. 12)
the
WHITE
wire
(~
OUTLET BOX--..
BLACK (HOT)
J
RECEIVER_
BLACK ("TO MOTOR
L")
BLUE-
BLACK (MOTOR)
6
......
.~
............
'.
Figure 10
Figure 11
WHITE (NEUTRAL)
GREEN OR BARE
COPPER (GROUNO)
WHITE ("AC IN N")
WHITE ("TO MOTOR
GROUND-(3
GROUND
(GREEN) ON CEILING FAN)
WHITE (NEUTRAL)
Figure 12
N"l
WIRES