Bose RoomMatch Manual de instalação - Página 3

Procurar online ou descarregar pdf Manual de instalação para Sistema de altifalantes Bose RoomMatch. Bose RoomMatch 24 páginas.

pro.Bose.com
I
ntroductIon
This document is intended to provide professional installers of sound reinforcement equipment basic guidelines for the design and
assembly of Bose RoomMatch™ loudspeaker arrays. The document will list the Working Load Limits of each component and provide
general guidelines for determining the acceptable working loads for the entire array. In general, information that is available in other
documents for RoomMatch components is not duplicated in this document. Please see pro.Bose.com to download these files.
Component Description – Loudspeaker Modules
Each RoomMatch module is a 2-way, full-range loudspeaker designed to form progressive directivity arrays for fixed-installation sound
reinforcement of the highest-quality live music and speech. Overcoming the limitations of both line array and point-source conventional
designs, RoomMatch modules define a new category of loudspeaker by delivering unprecedented sound quality for a wide variety of
room sizes and shapes, acoustic requirements, and budgets. System flexibility provides precise, constant-directivity coverage, from
single modules up to 8-module arrays, to ensure consistent tonal balance for many different room shapes and acoustic requirements.
The full-range modules are shipped with integrated side-plate array rigging hardware. The rigging system is designed to allow fast con-
struction of typical fixed-installation arrays of up to 8 modules, while maintaining a 10:1 Safety Factor.
A companion subwoofer, the RoomMatch RMS215 module is also available for systems that require additional low-frequency level and
impact. The RMS215 module is designed to integrate with RoomMatch™ arrays using the optional side-plate mounting kit for suspend-
ed applications. The side plates are not required for floor-mounted installations.
Figure 1. RoomMatch™ RMS215 subwoofer module
Figure 3. RoomMatch™ Module Dimensions and Weights
Array
Coverage
Module
RMxx05
Any
RMxx10
Any
RMxx20
Any
RMxx40
Any
RMxx60
Any
RMS215*
Omni
*Dimensions and weight of RMS215 do not include RMSFLY rigging kit.
Inches
Height
Width
5
16.9
39.1
10
17.9
39.1
20
20.0
39.1
40
24.0
39.1
60
27.5
39.1
Omni
17.8
37.1
Figure 2. RoomMatch™ RM7020 module
Dimensions and Weights
Dimensions
Depth
Height
23.6
428
23.6
455
23.6
509
23.6
610
23.6
700
21.8
452
Components
mm
Width
Depth
lb
993
598
123
993
598
123
993
598
123
993
598
124
993
598
125
943
553
132
Installation and Safety Guidelines
Net Weight
kg
55.8
55.8
55.8
56.3
56.7
59.9
Page 3