PROBLEMS
ON POSITION 6 (MAXIMUM)
THE FLAME IS LONG AND
SMOKY,
THERE
IS
BUILD UPON THE GLASS.
ON POSITION 1 (MINIMUM)
THE FLAME PRODUCES
SMOKE AND SUITS THE
GLASS.
ON POSITION 1 (MINIMUM)
THE FLAME PRODUCES
SMOKE AND SUITS THE
GLASS.

TROUBLESHOOTING GUIDE

CAUSES
Position 6 was reached too
quickly.
SUIT
Maximum flow is too high.
Cleaning tee and/or burner are
dirty.
Orifice of plunger is partially
plugged.
Flow is to low.
Page 11 of 15
SOLUTION
1. Set flow regulating handle
to position 1;
2. wait
for
combustion
stabilize;
3. Progressively increase flow
to desired position.
NOTE :
SEE
LIGHTING
PROCEDURES.
1. Set flow to a lower position;
2. Call a qualified technician
to adjust the valve.
1. Activate
cleaning
according to procedures;
2. Schedule at the next shut
off to clean the burner.
1. Progressively increase flow
to position ''6'';
2. Push in many consecutive
times on the thermostatic
regulator bottom to remove
dirt form the orifice.
NOTE : If the problem persist,
you may have to remove and
clean out the valve with alcohol.
Call
your
specialized
technician.
1. Slightly increase the flow
regulating handle;
2. Call
a
specialized
technician.