Anly APT-9S Manual do utilizador
Procurar online ou descarregar pdf Manual do utilizador para Temporizador Anly APT-9S. Anly APT-9S 2 páginas. Weekly programmable timer
Também para Anly APT-9S: Manual do utilizador (2 páginas)
APT-8S / APT-9S
WEEKLY PROGRAMMABLE TIMER
User's Manual
User's Manual
RESTRICTIONS ON USE
When using this product in applications
that require particular safety or when
using this product in important facilities,
please pay attention to the safety of the
overall system and equipment. Install fail-
safe mechanisms, perform redundancy
checks and periodic inspections and
adopt other appropriate safety measures
when it is necessary. This product is rated
at Class Ⅱ
.
SPECIFICATIONS
AC/DC : 12 ~ 48V / AC/DC : 100 ~ 240V
Operating voltage
Allowable operating
85 ~ 110% of rated operating voltage
voltage range
Rated frequency
50 / 60 Hz
Contact rating
240VAC 7A(N.O.), 240VAC 5A(N.C.) Resistive load
POWER - Red / RELAY ON - Green
Status Indicator
Power consumption
Approx. 3.3VA
Life
Mechanical : 5,000,000 times / Electrical : 100,000 times
o
Ambient temperature
-10 ~ +50
C
Ambient humidity
MAX 85% RH
Weight
Approx. 170g
CLOCK MODE
(Day and Time are flashing under this mode.)
MO
Clock Setting
START MODE
MO
CLK
Start
PROGRAM MODE
TIMER
Timer Output
PULSE
MO
ON
S T
E
Timer Setting
HR
TU
OFF
S T
E
Set Hour
Example :
A machine is turned on at 8:00 AM and turned off at 5:00 PM, from Monday to Friday. In addition, the machine is turned on between
9:00 AM and 11:00 AM on Saturday for inspection. The correct setting is as followed:
MO TU WE TH FR
ON
AM
S T
E
TIMER
Pulse Output
PULSE
S T
E
Pulse Setting
MIN
MO TU
ON
S T
E
Set Minute
SAFETY PRECAUTION
SAFETY PRECAUTION
WARNING
WARNING
CAUTION
CAUTION
‧Note this incorrect wiring of this controller can damage it and lead to other hazards. Make sure the controller has
been correctly wired before turning the power ON.
‧Before wiring, or removing / mounting the controller, be sure to turn the power OFF. Failure to do so might cause
electric shock.
‧Do not touch electrically charged parts such as the power terminals. Doing so might cause electric shock.
‧Do not disassemble the controller. Doing so might cause electric shock or faulty operation.
‧Use the controller within the operating ranges recommended in the specification (temperature, humidity, voltage,
shock, mounting direction, atmosphere and etc.). Failure to do so might cause fire or faulty operation.
‧Firmly tighten the terminal screws. Insufficient tightening of terminal screws might cause electric shock or fire.
‧Press reset before use after turning the battery on or replace the battery.
OPERATING FLOWCHART
DAY
HR
SU
MO
TU
WE TH FR SA
TU
Set Day of Week
Set Hour
12/24H
MO
CLK
AM
PM
Set 12H OR 24H
DAY
For APT-8S
DAY
MAN
For APT-9S
SU
MO
TU
WE TH FR SA
ON
S T
E
Set Day of Week
MIN
TU
OFF
S T
E
Set Minute
MO TU WE TH FR
OFF
S T
E
PM
SEC
S T
E
Set Pulse Width (Second)
CLEAR
MO TU
ON
S T
E
Program Enable Or Disable
This manual uses the following symbols to ensure safe operation of this timer.
Warnings are indicated when mishandling this controller might result in death or serious injury
to user.
Cautions are indicated when mishandling this controller might result in minor injury to the user,
or only physical damage to the timer.
BUTTON and SWITCH FUNCTIONS
‧
: Day of Week Setup
DAY
DAY
‧
: Hour Setup
HR
HR
‧
: Minute Setup
MIN
MIN
‧
: Second Setup
SEC
SEC
‧
: Mode Selection
MODE
MODE
‧
: Program Selection
PROG.
PROG.
‧
: Start Mode
START
START
‧
: Clear Setting
CLEAR
CLEAR
‧
: 12H or 24H
12/24H
12/24H
OFF
ON
RESET
1
BAT.
OR
MIN
TU
Start Clearing EEPROM
Set Minute
APT-9S only
APT-9S only
(
MODE
2
Switch to
START MODE
+1H
MO
+
1h
CLK
Set Daylight-Saving-Time
MODE
3
Switch to
PROGRAM MODE
HR
TU
ON
S T
E
Set Hour
CLEAR
TU
OFF
S T
E
Program Enable Or Disable
SA
ON
AM
S T
E
PROG.
MO
ON
S T
E
Set Program Number
START
MO
CLK
Start Mode
WARNING
CAUTION
‧
: Daylight-Saving-Time
+1H
+1H
‧
: Manual Override
MAN
MAN
‧
: Program Reset
RESET
RESET
‧TIMER
TIMER : Timer Control
‧PULSE
PULSE : Pulse Output
‧min
min
: Twin Timer Unit - Hr : Min
‧sec
sec
: Twin Timer Unit - Min : Sec
‧ON
ON
: Power / Battery On
‧OFF
OFF
: Power / Battery Off
CLEAR
5S
TU
TU
S T
E
Clearing EEPROM
APT-9S only
APT-9S only
)
(
)
MAN
MO
ON
OFF
CLK
Manual ON or OFF
(Override Current Program)
MIN
TU
ON
S T
E
Set Minute
START
MO
CLK
Start Mode
SA
OFF
AM
S T
E
DAY
For APT-8S
DAY
MAN
For APT-9S
SU
MO TU
WE TH FR SA
ON
S T
E
Set Day of Week
TU
EEPROM Cleared
APT-9S only
APT-9S only
(
)
MAN
3S
MO
ON
OFF
CLK
Manual ON or OFF
(Override all Programs)
PROG.
TU
OFF
S T
E
Set OFF Time
HR
MO TU
ON
S T
E
Set Hour