Anly APT-9S Manual do utilizador

Procurar online ou descarregar pdf Manual do utilizador para Temporizador Anly APT-9S. Anly APT-9S 2 páginas. Weekly programmable timer
Também para Anly APT-9S: Manual do utilizador (2 páginas)

Anly APT-9S Manual do utilizador
http://waterheatertimer.org/Woods-timers-and-manuals.html#ingram
APT-8S / APT-9S
WEEKLY PROGRAMMABLE TIMER
User's Manual
RESTRICTIONS ON USE
When using this product in applications
that require particular safety or when
using this product in important facilities,
please pay attention to the safety of the
overall system and equipment. Install fail-
safe mechanisms, perform redundancy
checks and periodic inspections and
adopt other appropriate safety measures
when it is necessary.
SPECIFICATIONS
AC/DC : 12 ~ 48V / AC/DC : 100 ~ 240V
Operating voltage
Allowable operating
85 ~ 110% of rated operating voltage
voltage range
Rated frequency
50 / 60 Hz
Contact rating
250VAC 10A (Resistive load)
Indicator operating
POWER - Red / RELAY ON - Green
Approx. 3.3VA
Power consumption
Life
Mechanical : 5,000,000 times / Electrical : 100,000 times
-10 ~ +50 °C
Ambient temperature
Ambient humidity
MAX 85% RH
Weight
Approx. 170g
CLOCK MODE
MO
CLOCK SETTING
NORMAL MODE
MO
CLK
NORMAL
PROGRAM MODE
(Choose ONE method ONLY)
TIMER
TIMER METHOD
PULSE
MO
ON
S T
E
TIMER SETTING
HR
TU
OFF
S T
E
SET HOUR
Setting example :
There is a machine needed to be turned on at 8:00 AM and to be turned off at 5:00 PM, from Monday to Friday.
In addition, the machine needed to be turned on at 9:00 AM to 11:00 AM every Saturday for inspection.
The correct setting display should be as follows.
MO TU WE TH FR
ON
AM
S T
E
TIMER
PULSE METHOD
PULSE
S T
E
PULSE SETTING
MIN
MO TU
ON
S T
E
SET MINUTE
SAFETY PRECAUTION
Warnings are indicated when mishandling this controller might result in death or serious injury
WARNING
to user.
CAUTION
Cautions are indicated when mishandling this controller might result in minor injury to the user,
or only physical damage to the timer.
Note this incorrect wiring of this controller can damage it and lead to other hazards. Make sure the controller has
been correctly wired before turning the power ON.
Before wiring, or removing / mounting the controller, be sure to turn the power OFF. Failure to do so might cause
electric shock.
Do not touch electrically charged parts such as the power terminals. Doing so might cause electric shock.
Do not disassemble the controller. Doing so might cause electric shock or faulty operation.
Use the controller within the operating ranges recommended in the specification (temperature, humidity, voltage,
shock, mounting direction, atmosphere and etc.). Failure to do so might cause fire or faulty operation.
Firmly tighten the terminal screws. Insufficient tightening of terminal screws might cause electric shock or fire.
DAY
HR
MIN
SEC
MODE
PROG.
START
CLEAR
12/24H
OPERATING FLOWCHART
OFF
1
BAT.
DAY
SU
MO
TU
WE TH FR SA
SET WEEKDAY
2
12/24H
MO
CLK
AM
PM
SELECT 12H OR 24H
3
DAY
For APT-8S
DAY
MAN
For APT-9S
SU
MO
TU
WE TH FR SA
ON
S T
E
SET WEEKDAY
MIN
TU
OFF
S T
E
SET MINUTE
PROGRAM ENABLE OR DISABLE
MO TU WE TH FR
OFF
ON
S T
E
AM
PM
SEC
S T
E
SET PULSE WIDTH SECOND
SET PROGRAM NUMBER
CLEAR
MO TU
ON
S T
E
PROGRAM ENABLE OR DISABLE
This manual uses the following symbols to ensure safe operation of this timer.
WARNING
CAUTION
BUTTON and SWITCH FUNCTIONS
: Weekday setting
: Hour setting
: Minute setting
: Second setting
: Mode status selecting
: Program number setting
: Normal mode setting
: Clear setting
: 12H or 24H setting
ON
RESET
OR
HR
TU
SET HOUR
SET MINUTE
MODE
CHANGE TO THE NORMAL MODE
+1H
MO
+
1h
CLK
ON
OFF
SHIFT THE OUTPUT STATUS
SET SUMMER TIME
(MOMENTARY OPERATION)
MODE
CHANGE TO THE PROGRAM MODE
HR
TU
ON
ON
S T
E
SET HOUR
SET MINUTE
CLEAR
TU
OFF
S T
E
NORMAL MODE
SA
SA
OFF
S T
E
AM
S T
E
For APT-8S
PROG.
For APT-9S
MO
SU
ON
ON
S T
E
START
MO
CLK
NORMAL MODE
+1H
: Daylight-saving-time setting
MAN
: Mandatory contact enable or disable
RESET
: Program reset
TIMER : Timer mode
PULSE : Pluse mode
min
: Unit of minute (in TWIN TIMER)
sec
: Unit of second (in TWIN TIMER)
ON
: Power on (Battery on)
OFF
: Power off (Battery off)
MIN
CLEAR
TU
TU
CLEAR EEPROM(
MAN
MAN
MO
MO
CLK
ON
OFF
SHIFT THE OUTPUT STATUS
(PEMANENT OPERATION)
MIN
PROG.
TU
TU
OFF
S T
E
SET OFF TIME
START
MO
CLK
DAY
HR
DAY
MAN
MO TU
WE TH FR SA
MO TU
ON
S T
E
SET WEEK
SET HOUR
5S
S T
E
APT-9S only
)
3S
CLK
S T
E
S T
E