4.2 Connection to the mains

Connect the fixture to the mains with the power cord.
If the plug on the flexible cord is not the right type for your socket outlets,do not use an adaptor,but remove the plug from
the cord and discard.Carefully prepare the end of the the supply cord and fit a suitable plug.
The earth has to be connected!
The occupation of the connection-cables is as follows:

4.3 DMX-512 connection/connection between fixtures

The fixture is equipped with 3-pin XLR sockets for DMX input and output. Only use a shielded twisted-pair cable designed
for RS-485 and 3-pin XLR-plugs and connectors in order to connect the controller with the fixture or one fixture with
another.
Occupation of the XLR-connection:
DMX - output
XLR mounting-sockets (rear view):
Building a serial DMX-chain:
If you are using the standard DMX-controllers, you can connect the DMX-output of the controller directly with the DMX-
-input of the first fixture in the DMX-chain. If you wish to connect DMX-controllers with other XLR-outputs, you need to
use adapter-cables.
Connect the DMX-output of the first fixture in the DMX-chain with the DMX-input of the next fixture. Always connect output
with the input of the next fixture until all fixtures are connected.
Caution: At the last fixture, the DMX-cable has to be terminated with a terminator. Solder a 120 Ohm resistor between
Signal (–) and Signal (+) into a 3-pin XLR-plug and plug it in the DMX-output of the last fixture.
Building a master/slave-chain:
Connect the DMX-output of the master fixture in the data-chain with the DMX-input of the first slave. Always connect output
with the input of the next slave until all slaves are connected (up to 32 fixtures).
Caution: It's necessary to insert the XLR termination plug (with 120 Ohm) into the input of the master fixture and into the
output of the last slave fixture in the link in order to ensure the proper transmission on the data link.
Cable (EU) Cable (US)
Brown
Black
Liht blue
White
Yellow/
Green
Green
1 - Shield
2 - Signal (-)
3 - Signal (+)
Pin
International
Live
L
Neutral
N
Earth
DMX-input
XLR mounting-plugs (rear view):
7
DMX operation
Master/slave operation