10. Programming
Fig 3.2
Flowvis model / reference #
d 50mm / ref 90020
d 63mm / ref 90021
d 75mm / ref 90026
d 90mm / ref 90022
d 110mm / ref 90023
d 160mm / ref 90027
d 200mm / ref 90028
To proceed with programming, first locate the DIP switches on the back side
of the Digital display. Refer to the circled area in Fig.3.2.
Important Note: It is important to select the correct DIP switch position
based on BOTH the model (first column) and the pipe size (second column)
shown in the table below as multiple FlowVis models exist for the same pipe
diameter.
Pipe size
DN40 / d50mm / 1.5"
DN50 / d63mm / 2"
DN65 / d75mm / 2.5"
DN80 / d90mm / 3"
DN100 / d110mm / 4"
DN150 / d160mm / 6"
DN200 / d225mm / 8"
Fig 3.3 (left) The
default setting for
the DIP switches (all
switches set to the
OFF position).
11
DIP - Switch position
1
2
OFF
ON
ON
ON
OFF
OFF
OFF
ON
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
ON
ON
Fig 3.4 (left) DIP
switch number 1 set
to the ON position.
WWW.DRYDENAQUA.COM
3
4
ON
OFF
OFF
OFF
ON
ON
OFF