Daikin FTKS50FVM Manual de serviço - Página 13
Procurar online ou descarregar pdf Manual de serviço para Manipuladores de ar Daikin FTKS50FVM. Daikin FTKS50FVM 20 páginas. Removal procedure, 5.0/6.0/7.1 kw class, 15000/18000 btu/h class
Também para Daikin FTKS50FVM: Manual de serviço (20 páginas)
Si041254EE
Step
4
Cut the clamp.
5
Unfasten the 8 hooks
and remove each PCB.
6
Disconnect every
connector from each
PCB.
7
Cut the clamp.
8
Unfasten the 2 hooks
on the lower side, and
then the 2 hooks on the
upper side.
Remove the control
PCB.
Removal Procedure
Procedure
Display PCB
Signal receiver PCB
Hook
Buzzer PCB
INTELLIGENT EYE
sensor PCB
Upper hook
Lower hook
Clamp
(R23374)
Hook
(R23375)
Hook
(R17913)
Control PCB
(R17912)
PCBs
Points
Some models do not have
INTELLIGENT EYE sensor
PCB.
11