Daikin FTKS50FVM Servis Kılavuzu - Sayfa 13

Hava Kontrol Cihazları Daikin FTKS50FVM için çevrimiçi göz atın veya pdf Servis Kılavuzu indirin. Daikin FTKS50FVM 20 sayfaları. Removal procedure, 5.0/6.0/7.1 kw class, 15000/18000 btu/h class
Ayrıca Daikin FTKS50FVM için: Servis Kılavuzu (20 sayfalar)

Daikin FTKS50FVM Servis Kılavuzu
Si041254EE
Step
4
Cut the clamp.
5
Unfasten the 8 hooks
and remove each PCB.
6
Disconnect every
connector from each
PCB.
7
Cut the clamp.
8
Unfasten the 2 hooks
on the lower side, and
then the 2 hooks on the
upper side.
Remove the control
PCB.
Removal Procedure
Procedure
Display PCB
Signal receiver PCB
Hook
Buzzer PCB
INTELLIGENT EYE
sensor PCB
Upper hook
Lower hook
Clamp
(R23374)
Hook
(R23375)
Hook
(R17913)
Control PCB
(R17912)
PCBs
Points
Some models do not have
INTELLIGENT EYE sensor
PCB.
11