3onedata IES2100SL-16T-2LV Manual de instalação rápida - Página 2

Procurar online ou descarregar pdf Manual de instalação rápida para Interruptor 3onedata IES2100SL-16T-2LV. 3onedata IES2100SL-16T-2LV 3 páginas. Unmanaged industrial ethernet switch

9.
10/100Base-T(X) 100M copper port (1-5/8/16)
【Mounting Dimension】
Unit: mm
Model I
Model II
Model III
Notice Before Mounting:
Don't place or install the device in area near water or
moist, keep the relative humidity of the device
surrounding between 5%~95% without condensation.
Before power on, first confirm the supported power
supply specification to avoid over-voltage damaging the
device.
The device surface temperature is high after running;
please don't directly contact to avoid scalding.
【DIN-Rail Mounting】
The product adopts 35mm standard DIN-Rail mounting which
is suitable for most industrial scenes, mounting steps as
follows:
Check if the DIN-Rail mounting kit is installed firmly.
Insert the bottom of DIN-Rail mounting kit (one side
with spring support) into DIN-Rail, and then insert
the top into DIN-Rail.
Tips:
Insert a little to the bottom, lift upward and then insert
to the top.
Check and confirm the product is firmly installed on
DIN-Rail, then mounting ends.
【Disassembling DIN-Rail】
Power off the device.
After lifting the device upward slightly, first shift out
the top of DIN-Rail mounting kit, and then shift out
the bottom of DIN-Rail, disassembling ends.
Notice before power on:
Power ON operation: First insert the power supply
terminal block into the device power supply interface,
then plug the power supply plug contact and power on.
Power OFF operation: First, remove the power plug,
then remove the wiring section of terminal block. Please
pay attention to the above operation sequence.
【Power Supply Connection】
Provide 2 power inputs, and adopt
4-pin 5.08mm pitch terminal blocks.
The power input supports 1 power
supply alone or 2 power supply at
the same time; When two power
supplies input at the same time, it
supports redundant backup of power supply. If one power
supply fails, the device can still work normally without
interruption. Power supply supports anti-reverse connection,
which cannot power the device but won't damage it when it's
reversely connected. The definitions of power pin are shown
in the figure above, and the power input range is 12/24/48
VDC (49~60VDC).
【DIP Switch Settings】
Provide 4 pins DIP switch for function settings, where "ON" is
enable valid terminal. The definitions of DIP switch are as
follows:
Model I
DIP Switch Definition
Operation
Set the switch to ON to enable
port loop detection function.
When the loop is detected, the
Loop
1
communication of one port will
Detection
be blocked to avoid the storm,
and the indicator of the loop
port will flash to warn.