DTI HV-500 Descrição técnica - Página 13

Procurar online ou descarregar pdf Descrição técnica para Inversor DTI HV-500. DTI HV-500 18 páginas.

DTI HV-500 Descrição técnica
HV-500 TECHNICAL DESCRIPTION

PC CONNECTION AND CONTROL

You can connect the inverter with a USB to RS-232 adapter (for example: ATEN UC232A) to the PC, where
the inverter can be parameterized. Use the „H" connector 5. and 13. pins and ground to common
potential. The DTI Tool software can be run on the PC.
The DTI Tool compatible with windows 10 x86 or x64.
If you would like to use another operating system, please contact us
DTI Tool features:
Real time data analysis
Online data logging just with DTI Tool
Error checking and logging
Motor position sensor setup, inspection
Online motor control with keypad (very carefully)
Setting input parameters
Very detailed query of measured current and voltage (like oscilloscope)

WIRING

Analog and digital signal inputs and outputs are provided for switches, sensors, contactors, hydraulic
valves, CAN communications, RS232 communications and SSI communications.
The wiring must be carried out by a qualified person.
It must be paid attention to the equipotential bonding for components which are connected to the unit
and which do not have isolated inputs and outputs (equalizing connection GND). The equalizing currents
may destroy components and parts.
The units, the inductive and capacitive accessories as well as the power wiring can generate strong
electric and electromagnetic fields. These fields may be dangerous for persons having electronic medical
aids or appliances (e.g. cardiac pacemakers). Sufficient distance to these electrical parts must be
observed. The switch cabinet must be labeled accordingly.
Keep all wiring harnesses short and route wiring close to vehicle metalwork. Keep all signal wires clear of
power cables and consider the use of screened cable. Keep control wiring clear of power cables when it
carries analogue information - for example, accelerator wiring. Tie all wiring securely.
Do not apply power until you are certain the controller high power and signal wiring is correct and
has been double checked. Wiring faults will damage the controller.
Revision 1.31
(BETA
VERSION)
13