Auber Instruments WS Series Manual rápido - Página 14
Procurar online ou descarregar pdf Manual rápido para Controlador Auber Instruments WS Series. Auber Instruments WS Series 14 páginas. Programmable pid temperature controller with dual probe
Também para Auber Instruments WS Series: Manual rápido (15 páginas), Manual rápido (14 páginas), Manual de operação e instruções (18 páginas), Manual de operação e instruções (18 páginas)
normal operating mode and will start run the current program.
c.
Store your program as recipe (Single-step Mode)
Before you input your set temperature, check the PrG = off (accessed by LCK code "3").
Press SET key once, and then set C-1=150, press set again to confirm and exit. The
controller will go back to the normal operating mode and start running on this single-step
program.
To store current program back to recipe b2, long press SET, set LCK=2, choose b2,
press set to confirm and exit. Now your current program is stored as recipe b2.
d.
Recall your recipe to current program (Single-step Mode)
Before you input your set temperature, check the PrG = off (accessed by LCK code "3").
Long press SET, set LCK=1, choose b2, press set to confirm and exit.
Now the C-1 from the recipe b2 is recalled back to your current program. The controller
will start run at this temperature setting.
e.
Advanced example
This example will show you how the PrG mode can affect the saved and current
recipe/program.
1) Set PrG = on, select "b1" recipe:
C-1=120, E-1=t, t-1=2.0;
C-2= 290, E-2= F, F-2=160;
C-3=130, E-3=t, F-3=30.0;
2) Change PrG = off, now the current single-step program is:
C-1: 120.
3) Set current C-1 to 200, then store current program back to recipe b1. Now the b1
recipe is:
C-1: 200.
4) Change PrG = on, current b1 recipe is:
C-1=200, E-1= t, F-1=2.0;
C-2=190, E-2=F, F-2=160;
C-3= 130, E-3=t, F-3=30.0.
14