Dametric K-DDRS1 Manual do utilizador - Página 3

Procurar online ou descarregar pdf Manual do utilizador para Cabos e conectores Dametric K-DDRS1. Dametric K-DDRS1 4 páginas. Rotating cable

RMS
3
MOUNTING INSTRUCTION
3.1 DISMOUNT THE OLD CABLE
 Remove the cover for the TDC-sensor space in the rotor.
 Remove the locking piece for the cable.
 Remove the centering nut from the TDC-sensor.
 Disconnect the bayonet connector of the cable from the TDC-sensor.
 Remove the Safeset clutch.
 Remove the TVD-TA1 transducer.
 Remove the cable from the cable guide inside the rotating transformer.
 Disconnect the cable from the rotating unit by holding the covers of the connectors and pull
them gently apart.
 Remove the mounting clip for the cable on the centering plate.
 Remove the cover of the connector from the welded sleeve of the metal tube.
 Be careful of the connector and use no tools if not necessary.
 Mount the brass cage (DD-DH15G) with the hauling wire to the welded sleeve of the tube.
 Pull the cable from the transducer end thus replacing it with the hauling wire.
 Remove the brass cage from the welded sleeve.
3.2 MOUNT THE NEW CABLE
 Remove the cover of the contact from the welded sleeve of the metal tube of the new cable.
Be careful of the connector and use no tools.
 Mount the brass cage (DD-DH15G) with the hauling wire to the welded sleeve of the tube.
 Pull the hauling wire until the flange of the rigid metal tube of the cable rests on the designed
edge of the rotor.
 Connect the bayonet connector to the TDC-sensor. Be careful to the surface (dia 17 mm)
outside the bayonet since the gasket inside the centering nut uses it.
 Mount the centering nut to the transducer. Check that the surface on the TDC-sensor is flat so
that the surface works as a sealing together with the cupper washer on the centering nut.
 At the other end, remove the brass cage and mount the attached O-ring and the cover of the
connector, use the attached tool to prevent rotation of the inner set.
Be careful of the connector parts.
 Slide the cable through the hole of the centering plate and the coupling flange.
 Fasten the cable to the centering plate with the mounting clip.
 Connect the cable to the rotating unit by holding the covers of the contacts, position the
male/female by rotating them and then push them gently together.
 Place the cable in the cable guide inside the rotating transformer, and mount the locking
screw.
 Mount the TVD-TA1 transducer.
 Mount the Safeset clutch.
K-DDRS1 EN.docx
Nov. 15, 2016 / DW
K-DDRS1
3(4)