The hood can be used for both filtering and suction.
When the filtering function is operating, i.e. with air
recycle, carbon filters must be used.
When the suction function is operating i.e.
exhausting the filtered air on the outside, a suitable
compensation system must be used according to
current standards in force. The diameter of the
fume exhaust pipe must be the same or greater
than the diameter of the hood pipe union.
There must be sufficient ventilation in the room
where the hood is installed, to allow simultaneous
use of other appliances that use gas or other fuels.

4.1 Assembly Instructions

Attention: Before proceeding with the installation,
make sure that the screws and the anchors already
supplied, are suitable for the type of ceiling the
hood must be fixed to.
To assemble the hood use the accessories that are
supplied and follow the instructions given in the
enclosed hand book.
Screw hole dimensions and cable entries
7
OPTIONAL OUTPUT POWER CABLE
490
OUTPUT POWER CABLE
75
Ø9mm hole
1. Drill a Ø4mm hole in the bulkhead (Fig 3) at the 4
anchor locations (Fig 2).
2. Screw the cap onto the bolt (Fig 4).
Fig 1
3. Screw the bolts into the 4 holes leaving 15mm
from bulkhead to end of the bolt and cap (Fig 5).
Fig 2
Ø4mm
Fig 3
Fig 4
5