Dukane iQ LS-E Nota de aplicação - Página 15
Procurar online ou descarregar pdf Nota de aplicação para Fonte de alimentação Dukane iQ LS-E. Dukane iQ LS-E 16 páginas. Ultrasonic probe system, automation interface guidelines
DUKANE
Intelligent Assembly Solutions
L
L
S
S
/
/
L
L
S
S
-
-
E
E
W
W
i
i
t
t
h
h
M
M
P
P
C
C
Probe selection changed between weld cycles: Although the probe selection can be changed at any time this method
is the safest and most predictable. The PLC program should monitor the MPC Ready output and when it becomes active
change the probe selection using the Remote Setup inputs. This will insure that the stack ring down from the previous
cycle is finished. After a delay of at least 33ms, the MPC Ready output will change to inactive (low in this case) again and
stay that way for 33ms. See Figure 3 where Remote Setup 0 changes from low to high. The PLC should continue to
monitor the MPC Ready output and start the next cycle when MPC Ready activates (high in this case).
Probe selection changed during a weld cycle: Alternately the Remote Setup inputs can change during the weld cycle.
The MPC circuitry will not select a new probe when the MPC Ready output is not active. As can be seen in Figure 3,
Remote Setup 0 input is changed to inactive before the weld cycle completes. Once the stack ring down completes the
relays switch so that probe 1 is selected almost immediately, but the relay takes up to 8ms to settle. The MPC Ready
output will remain inactive for 33ms after ring down completes. In this case the PLC must monitor the MPC Ready output
and not activate the U/S Activate input until the MPC Ready signal is active.
Timing Diagram Notes: All Signals are active high and the grey areas indicate that the output could be either high or low.
symbol indicates a time break so that the time where nothing is happening doesn't need to be shown.
The
AN502 (REV 07)
Page 15 of 16
Q
Q
(
(
W
W
e
e
l
l
d
d
-
-
b
b
y
y
-
-
A
A
u
u
t
t
o
o
m
m
a
a
Figure 3 LS / LS-E with MPCQ Weld Cycle (Weld-by-Automation)
t
t
i
i
o
o
n
n
)
)
T
T
i
i
m
m
i
i
n
n
g
g
D
D
i
i
a
a
g
g
r
r
a
a
APPLICATION NOTE
m
m
© Dukane 2016. All Rights Reserved.
AN502