Danfoss FP975 Manual de instalação - Página 4
Procurar online ou descarregar pdf Manual de instalação para Termostato Danfoss FP975. Danfoss FP975 16 páginas. 7 day electronic programmer with separate outputs for heating & hot water, which can be set at independent times.
Também para Danfoss FP975: Manual do utilizador (16 páginas), Instruções para o utilizador (2 páginas)
1.0 Installation Guide
Please Note:
This product should only be installed by a qualifi ed electrician or
competent heating installer and should be in accordance with the
current edition of the IEEE wiring regulations.
2.0 System Overview
GB
Specifi cation
Power supply
Switching action
Switch rating
Battery back-up
Timing Accuracy
Setting/Running Accuracy
Max. Ambient Temperature
Dimensions, mm (W, H, D)
Design standard
Control Pollution Situation
Rated Impulse Voltage
Ball Pressure Test
3.0 Installation
3.1 DIL Switch Settings
Before mounting the unit, ensure the 4 DIL switches on the rear of
the unit have been moved to the required settings.
4
For latest prices and delivery to your door visit MyTub Ltd - 0845 303 8383 - www.mytub.co.uk - [email protected]
TOP
LEFT
230 Vac ± 15%, 50/60 Hz
2 x SPDT voltage free, Type 1BS
10-230 Vac, 3(1)A
24 hours minimum
±1 min/month
±1 minute
45°C
148 x 96 x 42
EN 60730-2-7
Degree 2
2.5kV
75°C
RIGHT
FP975