Danfoss APPW 5.1 Manual de serviço - Página 10

Procurar online ou descarregar pdf Manual de serviço para Bomba de água Danfoss APPW 5.1. Danfoss APPW 5.1 12 páginas. Disassembling and assembling

Danfoss APPW 5.1 Manual de serviço
Disassembling and Assembling, APP(W) 5.1-10.2
Service guide |
10 | 180R9238 | DKCFN.PI.078.F3.02 | 521B1196
13. Place the guide pin in the casing. Position
the combined flange and swash plate onto
the guide pin and press it gently, by hand,
into the casing.
Ensure not to squeeze the O-ring.
15. Remove the ceramic ring from the seal
retaining ring.
16. Wet the parts with clean filtered water.
12. Remove the old O-ring and fit the
new O-ring on the adapter.
Guide pin
14. Screw the 8 screws into the flange and
the casing. To prevent cold welding,
lubricate the threads on the 8 screws
with grease, screw them into the pump
and tighten by hand. Use Molykote® D
paste from Dow Corning or Klüber UH1
84-201 from Klüber lubrication.
© Danfoss | DCS (im) | 2017.06