Danfoss APPW 5.1 서비스 매뉴얼 - 페이지 10
{카테고리_이름} Danfoss APPW 5.1에 대한 서비스 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Danfoss APPW 5.1 12 페이지. Disassembling and assembling
Disassembling and Assembling, APP(W) 5.1-10.2
Service guide |
10 | 180R9238 | DKCFN.PI.078.F3.02 | 521B1196
13. Place the guide pin in the casing. Position
the combined flange and swash plate onto
the guide pin and press it gently, by hand,
into the casing.
Ensure not to squeeze the O-ring.
15. Remove the ceramic ring from the seal
retaining ring.
16. Wet the parts with clean filtered water.
12. Remove the old O-ring and fit the
new O-ring on the adapter.
Guide pin
14. Screw the 8 screws into the flange and
the casing. To prevent cold welding,
lubricate the threads on the 8 screws
with grease, screw them into the pump
and tighten by hand. Use Molykote® D
paste from Dow Corning or Klüber UH1
84-201 from Klüber lubrication.
© Danfoss | DCS (im) | 2017.06