Installation Guide
2.5 Installing the Bottom Cover (Before Pedestal)
Use the following steps to install the bottom cover before attaching the pedestal. See
Procedure
1.
Remove paper backing from the bottom gasket.
2.
Adhere the bottom gasket to the upper side of the bottom cover.
3.
Position the bottom cover and gasket over the opening at the lower end of the cooling channel.
4.
Secure the bottom cover using the M5x14 screws (T25) provided with the kit.
Torque screws to 2.3 Nm (20 in-lb). FK11/FB11 frequency converters require 8 screws; FK12/FB12 frequency converters
require 10 screws.
Illustration 4: Installation of Bottom Cover and Pedestal
1
Cooling channel
2
Bottom gasket
3
Bottom cover
6 | Danfoss A/S © 2022.08
Illustration
4.
4
M5x14 screw
5
Pedestal
6
M10x30 fastener
AN361429087579en-000101 / 136R0289