MAINTENANCE
Your tool requires lubrication every day you use it.
Disconnect the air supply from the tool before lubricating.
Turn the tool so the inlet is facing up and put 6-8 drops of pneumatic
oil, part number 403720, into the air inlet. (See Fig 2).
Never use detergent oil or additives. Operate the tool briefly after
adding oil.
Wipe off excessive oil at the exhaust. Excessive oil will damage O-
rings of tool. If in-line oiler is used, manual lubrication through the air
inlet is not required on a daily basis.
CLEANING THE TOOL
NEVER USE GASOLINE OR OTHER FLAMMABLE LIQUIDS TO
CLEAN THE TOOL. VAPORS IN THE TOOL MAY IGNITE BY A
SPARK AND CAUSE THE TOOL TO EXPLODE AND RESULT IN
DEATH OR SERIOUS PERSONAL INJURY.
SOLVENTS USED TO CLEAN THE NOSE OF THE TOOL AND CON-
TACT SAFETY TRIP MECHANISM MAY SOFTEN THE TAR ON THE
SHINGLES AND CAUSE THE BUILDUP TO BE ACCELERATED.
MAKE SURE TO DRY THE TOOL THOURGHLY AFTER CLEANING
AND BEFORE OPERATIONG THE TOOL AGAIN.
1. Disconnect the air supply from the tool.
2. Remove tar buildup with kerosene, #2 fuel oil or diesel fuel. Do not allow
solvent to get into the cylinder or damage may occur. Dry off tool completely
DUO-FAST
before use.