Procurar online ou descarregar pdf Instruções para Aquecedor Consort Claudgen QZWP45N Series. Consort Claudgen QZWP45N Series 5 páginas. Infrared ip55 heater

2. INTRODUCTION & SPECIFICATION
This heater produces a totally dry heat, no condensation, no gas, no fumes and no smell. It reaches maximum heat output within seconds of being turned
on and has a highly polished aluminium reflector for maximum heat efficiency. It adjusts horizontally through 90° while mounted. And is Ideal for
industrial or domestic applications, IP55 rated.
Model
Power
Input supply
Dimensions (W x H x D)
Mounting Bracket Stand Off
Minimum Mounting Height

3. MOUNTING INSTALLATION

3.1
WALL MOUNTING (fig.1)
IMPORTANT! The following points should be noted: The heater
should always have a minimum clearance of 500mm from a
ceiling and at least 1000mm from any object.
IMPORTANT! Ensure that the mounting surface is capable of
supporting the weight of the heater.
IMPORTANT! The heater should be mounted horizontally where
possible or at a maximum angle of 35 degrees from the horizontal.
IMPORTANT! The mounting bracket must be sufficiently earthed.
3.1.1 Remove the wall mounting bracket from the heater by removing the
two bolts from either end of the bracket.
3.1.2 Before drilling ensure that there are no wires or water pipes in the
area where the heater is to be placed.
3.1.3 Use the bracket as a template. Fix the metal bracket to the wall by
using a minimum of 3 holes and appropriate fixings (not supplied).
3.1.4 Refit the heater back onto the bracket
3.1.5 Adjust the angle of heater to direct heat where required, between 45°
and 90° (see fig.1).
3.1.6 Now tighten up the two bolts tightly.
3.3

ELECTRICAL CONNECTION

3.3.1 Please make sure you have read the Safety instructions and
you are a suitably qualified electrician before continuing.
3.3.2 If connecting to a 20A Round Pin Industrial Plug
a) Connect the GREEN/YELLOW earth wire to the earth terminal 'E'.
b) Connect the BROWN live wire to the live terminal 'L'.
c) Connect the BLUE neutral wire to the neutral terminal 'N'.
d) After wiring, check that there are no bare wires, that all wires have
been correctly connected, that the cable outer insulation extends
beyond the cable restraint and that the restraint is tight.
3.3.3
Connection to a Switched Fused Spur / Isolator.
a) Connect the GREEN/YELLOW earth wire to the earth connection.
b) Connect the BROWN live wire to the live connection.
c) Connect the BLUE neutral wire to the neutral connection'.
d) After wiring, check that there are no bare wires, that all wires have
been correctly connected, that the cable outer insulation extends beyond the cable restraints and that the restraint is tight.
36000405
QZWP45N Series
4500W
240V 50Hz 18.75A
1440 x 125 x 125mm
45mm
1.8m