Aplisens CS-27/W Manual de instruções - Página 9
Procurar online ou descarregar pdf Manual de instruções para Instrumentos de medição Aplisens CS-27/W. Aplisens CS-27/W 13 páginas. Hydrostatic fuel level probe for installation on the fuel filler
Screw the bottom body (1) with three screws (5) to tank filler.
Screw the upper body (2) with seal II (4) to lower body (1) with two M4x25 screws (6).
Secure the wire with protective pipe, clamp the pipe at wire outlet with cable tie, lead the
wire into driver's cabin in such a way as to minimize possible thermal and mechanical
damage resulting from regular usage of vehicle.
Thread the sealing cord through the opening in screw head locking screw, wrap it around
the protective pipe and seal it.
Screw the cap on. Unscrew and screw the cap back on several times to verify the
stability of mounting on the tank filler.
CONNECTION
1.
All connection and installation steps must be performed with power disconnected.
02.B.003
Probe electrical outlets diagram:
IO.CS-27/W.CS-27/BAK
7