Apogee Symphony I/O Instruções e Manuais - Página 4
Procurar online ou descarregar pdf Instruções e Manuais para Equipamento de gravação Apogee Symphony I/O. Apogee Symphony I/O 9 páginas.
Symphony 64 PCI
(Compatible with ProTools Native- not to be confused with ProTools
Native-HD)
✴ Software Release 2.1 or later must be downloaded from Apogeedigital.com and
installed. Following installation restart your computer.
✴ Power off Symphony I/O.
✴ Connect Symphony I/O to Symphony 64 card 1, port 1.
✴ Power up unit. Set Symphony I/O to "Symphony" Audio Interface Mode (hold in the
right encoder to check and change needed)
✴ Open "Audio MIDI Setup" (found in Applications > Utilities...) make sure "Symphony
64" is selected for input and output. Make sure the "Source" is set to "PCI Card 1,
Port 1 (Ch 1-32)".
✴ Wait for Symphony I/O to lock to Internal and display "INT" on the front-panel. (you
should hear relays clicking from the Symphony I/O and the exclamation mark icon
on the front-panel should go away) The clock source can be changed from front-
panel (hold in left encoder) or in Maestro 2.
✴ Launch Logic (or any other CoreAudio application) and make sure Symphony 64 is
the I/O for the app in the audio preferences.
NOTE: SBUS and VBUS are not available when using ProTools Native due to the 32
channel limit.