Data Signs PTL Remote Manual de operação e manutenção - Página 17

Procurar online ou descarregar pdf Manual de operação e manutenção para Equipamento de segurança Data Signs PTL Remote. Data Signs PTL Remote 19 páginas. Portable traffic lights

Fault Conditions

If any fault conditions occur as discussed throughout this document, the Portable Traffic
Lights will go to Red.
All critical faults are logged to a file on the SD card fitted to the Master Controller.
The faults logged are outlined below. Reference back to the Australian Standard is provided
in the table.
Fault ID
Description
0
Yellow
1
Red
2
Green
3
Beacon
6
Excessive Link
7
Conflicting Link
8
Link Timeout
10
Low Battery
11
Tilt
To view the current fault log file, select FAULT LOG  VIEW LOGS from the
Mode menu. Use the
The last fault logged is shown first.
A sample fault log entry may be:
F A U L T
X X / X X / X X X X
0 0
-
Y e l l o w
The time shown with each fault log entry is the time that this fault occurred since the Master
Controller was powered up. The second part is the Portable Traffic Light unit affected (i.e.
Slave#2 or Master). The last part of the entry is the fault description.
Note: The XX/XX/XXXX is not used for PTL Type-1.
You can also use an SD card reader on a laptop/PC to read the fault log files from the SD
card. The file will be in the LOGS directory on the SD card.
Turn the Master Controller OFF and remove the SD card from its slot, leave the power
and
arrow buttons to move through the fault log entries.
L O G
M A S T E R
( O p e n )
OFF while re-inserting the SD card.
P T L O P E R A T I O N S M A N U A L
( 1 / 1 )
0 0 : 0 0 : 1 4
17