Only fresh water can be used with this
system.
When feeding the CaviBlaster® with an alternate water source, the source must supply water at a volume
of greater than 5 gallons per minute at a maximum pressure of 70-psi. Connect the water source to the
inlet of the pressure pump (Figure-9). Ensure that the garden hose is connected to the pressure pump and
the water is on prior to starting the pressure pump.
To make sure the source is providing 5 gallons per minute try filling up a 5 gallon bucket in less than a
minute. Figure 10.
Fill up a 5 gallon bucket in less than one minute - Figure #10
Starting the CaviBlaster® power unit:
1. When using a pressurized water source, open the valve to supply water to the system.
2. Ensure that the system is primed with water and that there are no leaks in the system. The pressure
pump is a positive displacement pump and water must be supplied under pressure. Failure to pump feed
water to the pressure pump will result in damage to the pump.
3. Connect the 3/8" high-pressure hose to the quick-connect plug under the pressure-regulating unloader
(Figure-11). The high-pressure hose has a brass quick-connect socket on the end. The CaviBlaster® Model
0520-G can deliver the required pressure utilizing up to 300 feet of 3/8" diameter rubber hose.
Connect HP Hose to the quick connect under pressure regulator - Figure #11