7. Divers and nearby personnel must use appropriate hearing protection prior to starting the engine.
8. Be sure the engine run switch is on (figure 12). Set the choke knob to close the choke if the engine is
cold or has not been running (figure 13). If the engine has been running and is warm, leave the choke
open. Adjust the throttle lever (Figure 12) one-third of the way from "MIN" toward "MAX" for correct
engine start RPM. Pull the recoil start cord, (figure 14) (several times as necessary) until the engine starts.
If the engine does not start, release the choke and try again.
9. Once the unit is running and warm, move the throttle to Max. (figure 16)
The system is now ready to operate. (figure 17)
Throttle to Max position - Figure #16
Overall system set up - Figure #17
Recommendations for Effective Results.
Once the engine is throttled up to operating speed and the water trigger is pulled, the diver should find
the most effective distance between the gun nozzle and the surface being cleaned. When the diver is
ready to commence cleaning operations, ensure that the gun trigger is in the open or "ON" position, the
gun is submerged in the water and the water source is on, prior to throttling up the engine.
Ensure that the power unit operator and other people working in the vicinity of the power unit wear
appropriate hearing protection when the engine is running.