DustScan
Dust Consultancy and Dust Monitoring Services
DS500X
The new DS500X sampler unit has been
designed to be more robust and user-friendly than
its predecessor (see photo top right).
The sampler requires a 12V power supply, which
is achieved by the external battery packs
supplied. Please ensure these are fully charged
before use, using the battery charger provided.
Once the sampler has been connected to the
battery pack via the power cable (see DS500X
Installation Instructions Page 3) it can be
activated:
PLEASE NOTE - the sampler unit will not activate
if its SD card is missing (see middle photo right).
Switch the I/0 (on/off) rocker switch on the top
of the sampler unit to 'I' (on). The green 'ON'
LED will illuminate (see bottom photo right)
PLEASE NOTE - there is a 5 second delay
before the sampler pump activates. A whirring
noise will be audible when the pump is running
The sampler unit writes data to its SD card
every hour. Whilst data is being written, the red
'INFO' LED will flash 5 times
The sampler unit will automatically shut down
after exactly 7 days run time
PLEASE NOTE - the rocker switch does not
reset. At the end of a 7 day run OR to end a
sampling run prematurely, switch the rocker
switch to '0' (off). Again, there is a short time
delay until the pump de-activates.
Once the sampler has been activated the inlet
and monitoring head assembly must be replaced.
Please do not disconnect the power supply whilst
the sampler unit is running.
Please do not remove the sampler units side
inspection panels without prior agreement.
- Sampler Unit Operation